<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15368</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Timeout waiting for QSPI system to initialize, stepper drive task startup failed
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error should not be seen under normal machine operation.  Select RESET TRENDSETTER
from the workstation TRENDSETTER pull-down menu. If the problem persists,
call Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error is probably a hardware problem.  Check the MPE board, SPI cable, TEE baord
and power supplies.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The SPI system which communicates with the peripheral boards (TEE board) is not initializing.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:05 2008 PST
</Updated>
<Links>
</Links>
</Error>